Underground pipe jacking is a construction method that has been tried and tested for years, and that has well-known, undisputed advantages, especially in residential areas. At the same time this process makes particularly high demands on the pipe due to the extreme jacking loads applied during installation. The pipe must sustain these enormous forces and transfer them evenly and in a controlled manner, which requires perfect dimensional accuracy. Meyer-POLYCRETE has specialized in this application area. Our POLYCRETE® jacking pipes have proven their usefulness in this environment over decades.
The consistent use of high quality resins and aggregate materials in advanced recipes enables the pipes to reliably cope with high jacking forces. Thanks to a modern casting process with subsequent milling of the spigot ends the pipes feature excellent dimensional accuracy. And furthermore the very smooth, non-absorbing outer pipe surface minimizes static and dynamic friction and thus the breakaway and jacking resistance. This allows remarkable jacking lengths without using intermediate jacking stations.
SPECIFICATIONS
POLYCRETE® jacking pipes DN 250 - DN 1000
Internal diameter DN | External diameter da | Wall thickness s | Length L | Permissible jacking force* | Pipe weight** | |
---|---|---|---|---|---|---|
mm | (mm) | (mm) | (m) | t | (kN) | (kg/m) |
250 | 360 | 55 | 1 and 2 | 65 | 635 | 120 |
300 | 400 | 50 | 1 and 2 | 65 | 640 | 125 |
400 | 550 | 75 | 1 and 2 | 155 | 1560 | 255 |
500 | 660 | 80 | 2 | 200 | 1980 | 335 |
600 | 760 | 80 | 2 | 240 | 2350 | 390 |
700 | 860 | 80 | 2 | 260 | 2550 | 445 |
800 | 960 | 80 | 2 and 3 | 305 | 2990 | 505 |
900 | 1100 | 100 | 2 and 3 | 435 | 4300 | 720 |
1000 | 1185 | 92,5 | 2 and 3 | 425 | 4200 | 725 |
*) Minimum values for straight jacking in loose soil, with controlled installation, without pilot bore | **) Maximum values |
POLYCRETE® jacking pipes DN 1000 - DN 2000
Internal diameter DN | External diameter da | Wall thickness s | Length L | Permissible jacking force* | Pipe weight** | |
---|---|---|---|---|---|---|
mm | mm | mm | m | t | kN | kg/m |
1000 | 1185 | 92,5 | 2 und 3 | 405 | 3520 | 735 |
1000 | 1280 | 140 | 3 | 705 | 6150 | 1155 |
1200 | 1485 | 142,5 | 3 | 810 | 6280 | 1370 |
1400 | 1720 | 160 | 3 | 1025 | 7930 | 1810 |
1600 | 1940 | 170 | 3 | 1275 | 10250 | 2185 |
1800 | 2160 | 180 | 3 | 1500 | 12080 | 2580 |
2000 | 2400 | 200 | 3 | 1875 | 15080 | 3185 |
2200 | 2630 | 215 | 3 | 2170 | 21310 | 3755 |
*) Minimum values for straight jacking in loose soil, with controlled installation, without pilot bore | **) Maximum values |
POLYCRETE® jacking pipes DN 2200 - DN 2600
Internal diameter DN | External diameter da | Wall thickness s | Length L | Permissible jacking force* | Pipe weight** | |
---|---|---|---|---|---|---|
mm | mm | mm | m | t | kN | kg/m |
2400*** | 2870 | 235 | 3 | 2280 | 22400 | 4380 |
2600** | 3100 | 250 | 3 | 2600 | 25510 | 5150 |
*) Minimum values for straight jacking in loose soil, with controlled installation, without pilot bore | **) Maximum values | ***) Diameter only on request |
POLYCRETE® jacking pipes with kite-shaped profile DN 800 - DN 2000
Internal diameter DN | External diameter da | Wall thickness s | Length L | Permissible jacking force* | Pipe weight** | |
---|---|---|---|---|---|---|
mmh | mm | mm | m | t | kN | kg/m |
800 | 960 | 80 | 2 and 3 | 305 | 2990 | 565 |
1000 | 1185 | 92,5 | 2 and 3 | 405 | 4010 | 815 |
1000 | 1280 | 140 | 3 | 705 | 6930 | 1230 |
1200 | 1485 | 142,5 | 3 | 810 | 7990 | 1525 |
1400 | 1720 | 160 | 3 | 1025 | 10090 | 2125 |
1600 | 1940 | 170 | 3 | 1275 | 12520 | 2595 |
1800 | 2160 | 180 | 3 | 1500 | 14740 | 3025 |
2000 | 2400 | 200 | 3 | 1875 | 18400 | 3690 |
* Mindestwerte für Geradeauspressung in Lockerböden, bei kontrolliertem Einbau, ohne Pilotvortrieb | ** Maximalwerte |